SG-002 Analog 0-12V 0-24mA Signal Generator for PLC and Panel Debugging &amp Device Testing

SG-002 Analog 0-12V 0-24mA Signal Generator for PLC and Panel Debugging &amp Device Testing

Rs. 1,801.47
Sale price  Rs. 1,801.47 Regular price  Rs. 2,876.58
Skip to product information
SG-002 Analog 0-12V 0-24mA Signal Generator for PLC and Panel Debugging &amp Device Testing

SG-002 Analog 0-12V 0-24mA Signal Generator for PLC and Panel Debugging & Device Testing

Rs. 1,801.47
Sale price  Rs. 1,801.47 Regular price  Rs. 2,876.58

SG-002 Analog 0-12V 0-24mA Signal Generator for PLC and Panel Debugging &amp Device Testing

The SG-002 is a precision analog signal generator designed to simulate 0-12V voltage and 0-24mA current outputs for comprehensive testing and validation of PLC input modules, industrial control panels, and sensor-based automation systems. Industrial automation technicians, control system engineers, and panel commissioning professionals rely on this instrument to verify signal conditioning circuits, test analog input cards, and troubleshoot 4-20mA and 0-10V measurement loops without risking live system connections. This device eliminates the need for expensive function generators or complex test setups, providing a dedicated solution for field debugging of analog signal chains in industrial environments.

Product Overview

The SG-002 operates on the principle of precision voltage and current regulation, allowing independent control of analog output signals across two separate ranges. The dual-output capability enables simultaneous testing of voltage-input and current-input modules, making it invaluable for multi-channel PLC validation. The device utilizes high-stability analog circuits with potentiometric control, ensuring smooth and repeatable signal generation without digital quantization errors that plague lower-cost alternatives. Its compact form factor and front-panel controls make it suitable for both laboratory benches and field service applications where space is limited.

The SG-002 employs a linear potentiometer-based output architecture that guarantees monotonic signal progression across the entire range with minimal hysteresis. This analog-first design is superior to PWM-based generators for testing sensitive analog input circuits that require clean, noise-free signals. The unit provides isolated outputs to prevent ground loop interference when testing networked PLC systems or multi-module panels. With its straightforward push-button operation and clear analog dial readouts, technicians can quickly dial in test signals without requiring software configuration or learning curves.

Key Specifications

Specification Details
Product Type Portable Analog Signal Generator
Voltage Output Range 0-12V DC adjustable
Current Output Range 0-24mA DC adjustable
Output Resolution Continuous analog adjustment
Load Impedance Voltage mode: 10 kOhm minimum, Current mode: 500 Ohm maximum
Accuracy ±2% of full scale
Temperature Stability ±0.05% per degree Celsius
Output Isolation Galvanically isolated from mains
Power Supply AC 230V 50Hz or DC battery operation
Warranty 7 days on manufacturing defects
Shipping 1-5 days from Bengaluru
Delivery 7-8 days across India
Support 24/7 via Email and WhatsApp

Key Features

  • Dual independent outputs for simultaneous 0-12V and 0-24mA signal generation, enabling parallel testing of voltage and current input modules without switching
  • Precision potentiometric control with smooth analog adjustment, eliminating step-wise digital quantization that can mask real-world signal behavior
  • Galvanic isolation between output and input stages, preventing ground loop currents that corrupt measurements in multi-module PLC systems
  • Compact portable design with integrated carrying handle, suitable for field commissioning, troubleshooting, and on-site panel validation work
  • Battery and mains operation flexibility, allowing use in locations without reliable AC power during remote industrial site testing
  • Low output impedance in current mode ensures accurate 4-20mA loop simulation across varying load resistances typical in sensor circuits

Applications and Use Cases

  • PLC analog input module commissioning: Inject calibrated 0-12V signals to verify correct scaling, offset, and linearization of analog input cards before connecting live sensors
  • 4-20mA transmitter simulation: Generate precise current loop signals to test pressure, temperature, and level sensor input modules without requiring actual field instruments
  • Control panel debugging: Inject known analog signals into panel-mounted analog meters, controllers, and data acquisition systems to isolate signal conditioning faults
  • Sensor circuit troubleshooting: Verify analog signal paths from sensor output through conditioning circuits to PLC input, identifying noise, attenuation, or offset errors in the signal chain
  • SCADA system validation: Test remote terminal unit analog inputs with standardized signals to confirm correct data transmission and scaling across industrial networks
  • Automation equipment acceptance testing: Perform factory acceptance tests on newly commissioned control systems by injecting reference signals and comparing PLC-logged values against known inputs

How to Use

Begin by connecting the SG-002 to the device under test using appropriate shielded cables, ensuring proper grounding to minimize noise coupling. For voltage output testing, connect the positive and negative terminals to the analog input of your PLC or test device. For current loop testing, connect the SG-002 in series with the load (typically 250 ohm resistor for 4-20mA loops), ensuring the current path is complete. Power on the unit and allow 2-3 minutes for thermal stabilization before beginning precision measurements.

Adjust the voltage potentiometer smoothly across its full range while observing the corresponding readings on your PLC analog input display or external multimeter. Start at the minimum position and slowly increase to maximum, noting any non-linearity or dead zones that indicate signal conditioning problems. For current mode testing, set the potentiometer to generate the desired milliamp value and verify the output using a multimeter in series with the load. Repeat the test across multiple points (0%, 25%, 50%, 75%, 100%) to confirm linearity and identify any scaling errors in the PLC input module configuration. Document all readings for compliance records and system commissioning reports.

Frequently Asked Questions

Can the SG-002 generate 4-20mA signals for standard industrial transmitters?

Yes, the SG-002 0-24mA output range covers the standard 4-20mA industrial loop range. Simply adjust the potentiometer to the 4mA position for zero signal and 20mA for full scale. This makes it ideal for simulating pressure, temperature, and flow transmitters during PLC testing without requiring actual field sensors.

What is the difference between voltage mode and current mode output?

Voltage mode (0-12V) is used for testing analog inputs that measure voltage directly, such as 0-10V sensor outputs or analog potentiometer inputs. Current mode (0-24mA) is used for 4-20mA loop testing where the signal is transmitted as a current through a series circuit. The SG-002 provides both simultaneously, allowing you to test multiple input types on the same device without reconfiguration.

Is galvanic isolation important for PLC testing?

Yes, galvanic isolation prevents ground loop currents that can introduce measurement errors of 1-5% in sensitive analog circuits. When testing multi-module PLC systems or networked panels, ground loops can cause false readings and mask real signal conditioning problems. The SG-002 isolation ensures accurate test results that reflect actual sensor behavior without ground-induced noise.

Can I use the SG-002 for long-duration stress testing?

The SG-002 is designed for field commissioning and troubleshooting applications requiring intermittent use. For extended stress testing lasting hours, ensure adequate ventilation around the unit and monitor for thermal drift. The temperature stability specification of ±0.05% per degree Celsius means that in a 40-degree temperature rise, accuracy may drift by 2%, which is acceptable for most industrial testing but should be noted in precision calibration work.

When will I receive my order?

Orders are dispatched within 1-5 business days from our Bengaluru warehouse. Delivery takes 7-8 days to most locations across India.

What is your return and warranty policy?

We offer a 7-day return policy on manufacturing defects only. Contact support within 7 days of receipt for free replacement or full refund. Not applicable for user damage or misuse.

Are bulk discounts available?

Yes, wholesale pricing for orders of 10 or more units. Contact our sales team via WhatsApp or email for a customized bulk quote.

Why Buy from The Tech Depot

  • Genuine Products: Sourced directly from authorized distributors with authentication
  • Expert Team: Our technical team validates every product before listing
  • Fast Shipping: Dispatched within 1-5 days from our Bengaluru warehouse
  • Pan-India Delivery: 7-8 days to Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata
  • Payment Options: COD, UPI, credit/debit cards, net banking, EMI available
  • Technical Support: 24/7 expert guidance via email and WhatsApp
  • Returns: 7-day return policy on manufacturing defects only

Buy SG-002 Analog 0-12V 0-24mA Signal Generator for PLC and Panel Debugging &amp Device Testing Online in India

Purchase the SG-002 Analog 0-12V 0-24mA Signal Generator for PLC and Panel Debugging &amp Device Testing online at The Tech Depot, India's trusted source for genuine electronics. We deliver across Bengaluru, Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata, Ahmedabad, Jaipur, and Surat. Get the best price on SG-002 Analog 0-12V 0-24mA Signal Generator for PLC and Panel Debugging &amp Device Testing with fast shipping and expert support.

Our team in Bengaluru is available 24/7 to support your journey from product selection to project completion.