Real Time C101+
Shipping calculated at checkout.
Our team in Bengaluru is available reliable to support your journey from product selection to project completion.
The Real Time C101+ is a precision digital multimeter designed for professional electrical testing and troubleshooting in industrial and field applications. Electrical engineers, technicians, and maintenance professionals rely on this instrument to measure voltage, current, resistance, and continuity with high accuracy across AC and DC circuits. This meter solves the critical problem of quick fault diagnosis and circuit validation in live electrical environments where speed and accuracy are non-negotiable.
Specifications
| Specification | Details |
| Product Type | Digital Multimeter - Professional Grade |
| Brand | Real Time |
| Origin | Original/Authentic |
| DC Voltage Range | 200mV to 1000V with 0.5% accuracy |
| AC Voltage Range | 200V to 750V True RMS with 1% accuracy |
| DC Current Range | 200µA to 20A with 1.2% accuracy |
| Resistance Measurement | 200Ω to 20MΩ with automatic range selection |
| Display Type | 3.5 digit LCD with backlight and auto-off feature |
| Safety Rating | CAT III 1000V / CAT IV 600V dual rated |
Why Choose Real Time C101+?
100% Authentic
GST Invoice - A GST invoice is included with every order.
Expert Support - Dedicated technical help on WhatsApp and email.
Pan-India Delivery - Shipped across Bengaluru, Delhi NCR, Hyderabad and all of India.
Trusted by Makers - Used by students, hobbyists and professionals nationwide.
Key Features of Real Time C101+
- True RMS measurement technology ensures accurate readings on distorted AC waveforms from variable frequency drives and non-linear loads
- Automatic range selection eliminates manual switching and reduces measurement time during troubleshooting procedures
- Overload protection circuit with fused inputs prevents permanent damage from accidental high-voltage exposure
- Dual CAT rating (CAT III 1000V / CAT IV 600V) enables safe testing in both industrial distribution and control circuit environments
- Data hold function captures and freezes readings for documentation and comparison during diagnostic procedures
- Continuity buzzer with visual indicator provides rapid feedback for circuit tracing and connection verification
Perfect For
- Industrial maintenance: Testing motor windings, control circuits, and power distribution systems in manufacturing facilities where downtime is costly
- Electrical installation verification: Validating proper wiring polarity, grounding continuity, and voltage presence before energizing new circuits
- HVAC troubleshooting: Measuring thermostat signals, contactor coil voltages, and compressor motor currents in commercial refrigeration systems
- Building automation diagnostics: Testing sensor inputs, relay outputs, and communication signals in building management system networks
- Field service calls: Rapid voltage and continuity checks in residential and commercial electrical panels to identify fault locations
How to Use
Begin by selecting your measurement type using the rotary dial on the front panel, positioning it toward DC voltage, AC voltage, current, resistance, or continuity as required. Insert the black probe into the COM (common) terminal and the red probe into the appropriate input terminal based on your measurement range - use the mA terminal for currents up to 200mA, or the 20A terminal for higher currents. Always ensure the meter is set to the correct measurement type before connecting probes to the circuit, and never attempt to measure current by connecting the meter in parallel across a component.
For voltage measurements, connect the probes across the component or between the point of interest and ground, keeping probes steady until the display stabilizes. The automatic range selection will adjust the measurement scale, but you can manually select a specific range by rotating the dial to a fixed position if you prefer. For resistance and continuity measurements, ensure the circuit is de-energized and isolated from power sources to prevent damage to the meter and ensure accurate readings. Always remove the probes from the circuit immediately after measurement is complete, and store the meter in a dry location away from extreme temperatures to maintain calibration accuracy.
Product Overview
The Real Time C101+ operates on the principle of digital signal conversion, utilizing a high-resolution analog-to-digital converter to translate electrical parameters into precise numerical readings on its LCD display. The device features automatic range selection technology that eliminates manual switching between measurement ranges, reducing operator error and increasing measurement speed. The internal circuitry incorporates overload protection mechanisms that safeguard the instrument against voltage spikes and transient surges, making it suitable for harsh industrial environments where power quality is unpredictable.
What distinguishes the C101+ model is its robust construction with dual CAT III safety rating, allowing safe operation on both low-voltage control circuits and higher-voltage distribution systems. The meter integrates a true RMS measurement capability for AC voltage and current, ensuring accurate readings even when measuring non-sinusoidal waveforms common in variable frequency drives and switching power supplies. The ergonomic design with rubberized grip and intuitive button layout enables single-handed operation, while the backlit display ensures visibility in dimly lit electrical rooms and underground installations.
Frequently Asked Questions
What does True RMS measurement mean and why is it important?
True RMS (Root Mean Square) measures the actual heating effect of an AC waveform, making it essential for non-sinusoidal signals. Unlike average-reading meters that assume pure sine waves, the C101+ calculates the true effective value of distorted waveforms from variable frequency drives, LED dimmers, and switching power supplies. This ensures accurate current and voltage readings in modern industrial environments where harmonic distortion is common.
Can I measure current without breaking the circuit?
No, current measurement requires the meter to be connected in series with the circuit, meaning you must break the circuit connection and insert the meter probes. Never attempt to measure current by connecting the meter in parallel, as this will create a short circuit and damage the meter's internal fuse. Always turn off power before connecting for current measurement, then turn power back on only after the meter is properly connected in series.
What is the difference between CAT III and CAT IV safety ratings?
CAT ratings indicate the meter's ability to withstand transient overvoltages. CAT IV 600V is for utility supply connections and outdoor installations where lightning surges are possible. CAT III 1000V is for industrial distribution systems and fixed installations. The C101+ dual rating means it can safely measure at 1000V in distribution systems but only up to 600V in outdoor utility environments. Always respect these limits as exceeding them risks arc flash and equipment damage.
Are bulk discounts available?
Yes, wholesale pricing for orders of 10 or more units. Contact our sales team via WhatsApp or email for a customized bulk quote.
Customer Support
Email: techdepotindia@gmail.com
WhatsApp: Available for setup and troubleshooting help
Order your Real Time C101+ today and start building your next project.