KCP-X-S04 Kamoer Lab Pump 24V 1A – S04 – 4~14ml/min | Silicone tube 1.0*3.3mm

KCP-X-S04 Kamoer Lab Pump 24V 1A – S04 – 4~14ml/min | Silicone tube 1.0*3.3mm

Rs. 2,424.22
Sale price  Rs. 2,424.22 Regular price  Rs. 3,484.22
Skip to product information
KCP-X-S04 Kamoer Lab Pump 24V 1A – S04 – 4~14ml/min | Silicone tube 1.0*3.3mm

KCP-X-S04 Kamoer Lab Pump 24V 1A – S04 – 4~14ml/min | Silicone tube 1.0*3.3mm

Rs. 2,424.22
Sale price  Rs. 2,424.22 Regular price  Rs. 3,484.22

KCP-X-S04 Kamoer Lab Pump 24V 1A – S04 – 4~14ml/min | Silicone tube 1.0*3.3mm

The KCP-X-S04 Kamoer Lab Pump is a precision peristaltic pump designed for accurate fluid transfer in laboratory and analytical applications, delivering a consistent flow rate between 4 to 14 milliliters per minute. This 24V DC pump with 1A current rating is engineered for researchers, chemists, and biotech professionals who require reliable, contamination-free liquid handling in titration, sample preparation, and automated dispensing systems. The pump solves critical challenges in maintaining precise dosing accuracy, preventing backflow contamination, and enabling hands-free operation in demanding laboratory environments.

Product Overview

The KCP-X-S04 operates on peristaltic pump technology, which uses rotating rollers to compress a silicone tube in a circular motion, creating a controlled pumping action that moves fluid without the pump head coming into contact with the liquid. This design principle ensures zero contamination of samples, making it ideal for pharmaceutical analysis, chemical dispensing, and biological research where sample integrity is paramount. The pump's 24V DC power requirement makes it compatible with standard laboratory power supplies and control systems, while the 1A current draw ensures efficient operation without excessive power consumption or heat generation.

The S04 model variant features a silicone tube with 1.0mm inner diameter and 3.3mm outer diameter specifications, engineered to handle viscous and aqueous solutions with equal efficiency. The flow rate range of 4 to 14ml/min provides flexibility across multiple laboratory protocols, from slow micro-dispensing applications to moderate-speed transfer operations. The peristaltic design inherently provides excellent repeatability and accuracy, with minimal pulsation and consistent volumetric delivery that meets ISO 9001 quality standards for laboratory equipment. The pump's compact form factor and low noise operation make it suitable for integration into automated systems, analytical instruments, and benchtop laboratory setups without requiring extensive modifications.

Key Specifications

Specification Details
Product Type Peristaltic Lab Pump
Brand Kamoer
Model KCP-X-S04
Origin Original and Authentic
Power Supply 24V DC
Current Rating 1A
Flow Rate Range 4 to 14 ml/min
Tube Inner Diameter 1.0mm
Tube Outer Diameter 3.3mm
Tube Material Silicone
Pump Type Peristaltic
Warranty 7 days on manufacturing defects
Shipping 1-5 days from Bengaluru
Delivery 7-8 days across India
Support 24/7 via Email and WhatsApp

Key Features

  • Precision Peristaltic Design: Non-contact pumping mechanism prevents sample contamination and allows handling of chemically aggressive or biological fluids without degradation
  • Accurate Flow Rate Control: 4 to 14ml/min range with consistent volumetric delivery ensures repeatability across multiple laboratory runs and protocols
  • Compact 24V DC Operation: Low voltage requirement with 1A current rating enables safe integration into benchtop systems and portable laboratory configurations
  • Silicone Tube Construction: 1.0mm x 3.3mm tubing provides optimal flexibility and durability for extended pump life with minimal wear on peristaltic rollers
  • Low Noise Operation: Smooth roller mechanism produces minimal vibration and acoustic noise, suitable for sensitive analytical environments
  • Reversible Flow Capability: Bidirectional pumping enables backflush cleaning and reverse flow applications for system maintenance and sample recovery

Applications and Use Cases

  • Pharmaceutical Titration Systems: Automated acid-base titration and potentiometric analysis where precise micro-dosing of titrant solutions is critical for accurate endpoint detection
  • Chemical Analysis and Sampling: Consistent sample introduction into analytical instruments such as spectrophotometers, chromatography systems, and mass spectrometers for reproducible results
  • Biological Research and Cell Culture: Sterile fluid transfer and nutrient medium dispensing in tissue culture applications where contamination prevention is essential
  • Laboratory Automation and Control Systems: Integration into automated liquid handling platforms, robotic sample processors, and continuous flow synthesis setups
  • Environmental Testing: Water quality analysis and pollutant detection systems requiring precise reagent addition and sample preparation protocols
  • Industrial Process Monitoring: In-line fluid transfer for quality control laboratories in food, beverage, and chemical manufacturing environments

How to Use

Begin by preparing your system components: ensure the silicone tube is properly seated in the pump head with both ends securely positioned, verify that the 24V DC power supply is rated for at least 1A output, and connect the inlet and outlet tubing to your fluid source and destination containers respectively. Prime the pump by running it for 5 to 10 seconds without load to remove air bubbles from the tubing and establish consistent flow. For initial operation, set the pump to its lowest flow rate setting and gradually increase to your desired 4 to 14ml/min range, observing the fluid delivery rate to confirm proper operation.

Connect the pump to your 24V DC power supply using the provided connector, ensuring proper polarity to avoid damage to the pump motor. Most Kamoer pumps feature simple on-off control, though advanced models may include variable speed controllers or PWM (Pulse Width Modulation) interfaces for flow rate adjustment. For laboratory integration, the pump can be controlled via relay modules, PLC systems, or Arduino-compatible microcontrollers for automated operation. After each use, flush the tubing with distilled water or appropriate cleaning solution to prevent residue buildup and maintain pump performance. Store the pump in a dry environment and replace the silicone tube every 6 to 12 months depending on usage frequency and fluid compatibility, as silicone naturally degrades over extended periods.

Frequently Asked Questions

What is the maximum pressure rating for the KCP-X-S04 pump?

The KCP-X-S04 is designed for low-pressure applications typical of laboratory fluid transfer, with a maximum operating pressure of approximately 0.3 to 0.5 bar. It is not suitable for high-pressure applications or systems requiring pressurization above 1 bar. For applications requiring higher pressure, consider alternative pump models with reinforced tubing and motor specifications.

Can the KCP-X-S04 pump handle viscous liquids or oils?

Yes, the peristaltic design of the KCP-X-S04 makes it suitable for handling viscous fluids including oils, glycerin solutions, and thick suspensions. However, extremely viscous fluids above 1000 cP may reduce flow rate and increase motor load. Test the pump with your specific fluid at the desired temperature to ensure compatibility and confirm actual flow rates match your application requirements.

How do I control the flow rate of the KCP-X-S04?

The KCP-X-S04 delivers fixed flow rates determined by the pump motor speed and tube diameter. Flow rate control is achieved through motor speed variation using PWM controllers, variable voltage supplies, or dedicated pump controllers with speed adjustment. The standard 4 to 14ml/min range can be fine-tuned by adjusting input voltage between 12V and 24V DC, though this may affect pump longevity. For precise flow control, external variable speed controllers are recommended.

Is the silicone tube food-grade and safe for drinking water applications?

The silicone tubing supplied with the KCP-X-S04 is laboratory-grade and suitable for general chemical and biological applications. For drinking water or food contact applications, verify that the tubing meets FDA CFR 177.2600 standards for food-contact silicone. We recommend contacting our technical team to confirm specific food-safety certifications for your application before deployment in consumable fluid systems.

When will I receive my order?

Orders are dispatched within 1-5 business days from our Bengaluru warehouse. Delivery takes 7-8 days to most locations across India.

What is your return and warranty policy?

We offer a 7-day return policy on manufacturing defects only. Contact support within 7 days of receipt for free replacement or full refund. Not applicable for user damage or misuse.

Are bulk discounts available?

Yes, wholesale pricing for orders of 10 or more units. Contact our sales team via WhatsApp or email for a customized bulk quote.

Why Buy from The Tech Depot

  • Genuine Products: Sourced directly from authorized distributors with authentication certificates and verification of product authenticity
  • Expert Team: Our technical team validates every product before listing and provides application-specific recommendations
  • Fast Shipping: Dispatched within 1-5 days from our Bengaluru warehouse with real-time tracking
  • Pan-India Delivery: 7-8 days to Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata, Ahmedabad, Jaipur, and Surat
  • Payment Options: COD, UPI, credit/debit cards, net banking, and EMI available for flexible purchasing
  • Technical Support: 24/7 expert guidance via email and WhatsApp for setup, troubleshooting, and application assistance
  • Returns: 7-day return policy on manufacturing defects with hassle-free replacement process

Buy KCP-X-S04 Kamoer Lab Pump 24V 1A – S04 – 4~14ml/min | Silicone tube 1.0*3.3mm Online in India

Purchase the KCP-X-S04 Kamoer Lab Pump 24V 1A – S04 – 4~14ml/min | Silicone tube 1.0*3.3mm online at The Tech Depot, India's trusted source for genuine laboratory and analytical equipment. We deliver across Bengaluru, Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata, Ahmedabad, Jaipur, and Surat. Get the best price on KCP-X-S04 Kamoer Lab Pump 24V 1A – S04 – 4~14ml/min | Silic

You may also like