{"product_id":"kamoer-kcp-c-lab-pump-s06-peristaltic-pump","title":"Kamoer KCP- C -LAB PUMP – S06 Peristaltic Pump","description":"\u003cmeta name=\"description\" content=\"Buy Kamoer KCP- C -LAB PUMP – S06 Peristaltic Pump online in India at best price from The Tech Depot, Bengaluru. Authentic product, 7-day warranty on manufacturing defects, fast delivery across India.\"\u003e\n\n\u003ch1\u003eKamoer KCP- C -LAB PUMP – S06 Peristaltic Pump\u003c\/h1\u003e\n\n\u003cp\u003eThe Kamoer KCP-C-LAB PUMP S06 is a precision peristaltic pump designed for accurate fluid transfer in laboratory and analytical applications requiring consistent flow rates and minimal pulsation. This pump is extensively used by pharmaceutical researchers, clinical laboratories, and analytical chemists who need reliable dosing of corrosive chemicals, viscous solutions, and sensitive biological samples without contamination. It solves critical challenges in automated liquid handling by delivering repeatable accuracy between 0.1 to 600 mL\/min while maintaining sample integrity and preventing backflow.\u003c\/p\u003e\n\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Kamoer KCP-C-LAB PUMP S06 operates on the peristaltic pumping principle, where rotating rollers compress a flexible silicone tubing in a circular motion, creating expansion and contraction chambers that move fluid forward without the liquid contacting pump internals. This design eliminates cross-contamination risks, making it ideal for multi-channel applications and pharmaceutical workflows. The S06 variant features six independent channels, each capable of simultaneous operation with individual flow rate control, enabling parallel sample processing and high-throughput laboratory automation.\u003c\/p\u003e\n\n\u003cp\u003eThis model stands out through its brushless DC motor technology that delivers smooth, pulsation-free flow with minimal noise generation, critical for sensitive analytical measurements. The pump incorporates a microprocessor-controlled system allowing programmable flow rates, reversible operation for backflush cleaning, and real-time monitoring of pump status. Its compact laboratory form factor integrates seamlessly into existing benchtop setups while the modular tubing design permits quick changeover between different fluid types without cross-contamination concerns.\u003c\/p\u003e\n\n\u003ch2\u003eKey Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecification\u003c\/td\u003e\n\u003ctd\u003eDetails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSix-Channel Peristaltic Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eKamoer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKCP-C-LAB PUMP S06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eOriginal\/Authentic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e7 days on manufacturing defects\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping\u003c\/td\u003e\n\u003ctd\u003e1-5 days from Bengaluru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelivery\u003c\/td\u003e\n\u003ctd\u003e7-8 days across India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport\u003c\/td\u003e\n\u003ctd\u003e24\/7 via Email and WhatsApp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e6 Independent Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Rate Range\u003c\/td\u003e\n\u003ctd\u003e0.1 to 600 mL\/min per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±2% of set flow rate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Type\u003c\/td\u003e\n\u003ctd\u003eBrushless DC Motor with Speed Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTubing Compatibility\u003c\/td\u003e\n\u003ctd\u003eStandard Silicone Tubing (Multiple Sizes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e110-240V AC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Pressure\u003c\/td\u003e\n\u003ctd\u003e0.8 MPa per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSix Independent Channels with individual flow rate control enabling simultaneous multi-sample processing and parallel analytical workflows without cross-contamination\u003c\/li\u003e\n\u003cli\u003ePrecision Flow Accuracy of ±2% ensuring repeatable dosing for pharmaceutical formulations, titrations, and quantitative chemical analysis\u003c\/li\u003e\n\u003cli\u003eBrushless DC Motor Technology delivering smooth, pulsation-free flow critical for sensitive spectrophotometric and chromatographic measurements\u003c\/li\u003e\n\u003cli\u003eMicroprocessor-Controlled Operation with programmable flow rates, reversible pumping direction, and real-time status monitoring via digital interface\u003c\/li\u003e\n\u003cli\u003eTubing-Free Design Principle where fluid contacts only the silicone tubing, eliminating pump corrosion and enabling safe handling of aggressive chemicals and biological samples\u003c\/li\u003e\n\u003cli\u003eCompact Benchtop Form Factor with modular construction for easy integration into existing laboratory automation systems and space-constrained environments\u003c\/li\u003e\n\u003cli\u003eQuick-Change Tubing System allowing rapid switchover between different fluid types and viscosity ranges without tools or recalibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications and Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePharmaceutical Quality Control and Formulation Testing where precise metering of active pharmaceutical ingredients, excipients, and solvents is required for batch consistency validation and stability studies\u003c\/li\u003e\n\u003cli\u003eClinical Laboratory Automation including automated serum analysis, immunoassay sample preparation, and reagent dispensing for high-throughput diagnostic testing\u003c\/li\u003e\n\u003cli\u003eChemical Analysis and Titration where accurate delivery of titrant solutions and analyte samples ensures reproducible results in volumetric analysis and endpoint detection\u003c\/li\u003e\n\u003cli\u003eBiomedical Research Applications including cell culture media transfer, enzyme substrate dispensing, and sample preparation for mass spectrometry and chromatography workflows\u003c\/li\u003e\n\u003cli\u003eWater Quality Testing and Environmental Monitoring for precise addition of test reagents and sample collection in field and laboratory settings\u003c\/li\u003e\n\u003cli\u003eFood and Beverage Analysis for accurate dosing of preservatives, additives, and test solutions during quality assurance and shelf-life stability studies\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003cp\u003eBegin by selecting appropriate silicone tubing compatible with your fluid chemistry and desired flow rate range from the Kamoer tubing compatibility chart. Insert the tubing into the peristaltic pump head, ensuring proper seating in the compression chamber, then secure the tubing ends to your source and destination containers using standard laboratory connectors. Power on the unit and access the digital control interface to set individual flow rates for each of the six channels using the microprocessor menu system, typically ranging from 0.1 to 600 mL\/min depending on tubing diameter and motor speed.\u003c\/p\u003e\n\n\u003cp\u003eFor accurate operation, prime each channel by running the pump in forward direction for 30 seconds to eliminate air bubbles and establish consistent flow before beginning your analytical procedure. Monitor the real-time flow status display to confirm each channel is operating within specification, and use the reversible pumping feature to backflush tubing with cleaning solution between different sample types to prevent carryover contamination. After completing your workflow, run the pump with distilled water or appropriate solvent for 60 seconds to flush residual fluid from the tubing, then allow the pump to air dry before storage to prevent microbial growth and tubing degradation.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is the maximum flow rate accuracy of the Kamoer KCP-C-LAB PUMP S06?\u003c\/summary\u003e\n\u003cp\u003eThe S06 model delivers ±2% accuracy of the set flow rate across its entire 0.1 to 600 mL\/min range per channel. This precision is maintained through brushless DC motor speed control and microprocessor feedback monitoring, making it suitable for quantitative analytical applications requiring repeatable dosing such as pharmaceutical assays and chemical titrations.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I operate all six channels simultaneously at different flow rates?\u003c\/summary\u003e\n\u003cp\u003eYes, the KCP-C-LAB PUMP S06 features six completely independent channels with individual microprocessor control. Each channel can operate at different flow rates simultaneously, allowing parallel processing of multiple samples or simultaneous dispensing of different reagents without any interaction or flow rate interference between channels.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat types of fluids can be safely pumped through the S06 peristaltic pump?\u003c\/summary\u003e\n\u003cp\u003eThe peristaltic design allows safe handling of corrosive chemicals, viscous solutions, and biological samples since fluid contacts only the silicone tubing and not pump internals. Compatible fluids include strong acids, bases, organic solvents, cell suspensions, and pharmaceutical solutions. Always verify tubing material compatibility with your specific fluid chemistry to prevent degradation or leaching.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow do I prevent cross-contamination between different samples?\u003c\/summary\u003e\n\u003cp\u003eThe six independent channels are physically isolated, preventing cross-contamination during simultaneous operation. Between different sample types, use the reversible pumping feature to backflush each tubing with appropriate cleaning solution such as distilled water or 70% ethanol for 60 seconds, then allow air drying before introducing new samples.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is the warranty coverage and what does it include?\u003c\/summary\u003e\n\u003cp\u003eWe provide a 7-day warranty on manufacturing defects covering motor failure, control board malfunction, and structural damage. This warranty covers replacement or full refund upon return of the defective unit. Warranty does not cover tubing degradation, user damage from improper handling, or damage from incompatible fluid chemistry.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhen will I receive my order?\u003c\/summary\u003e\n\u003cp\u003eOrders are dispatched within 1-5 business days from our Bengaluru warehouse. Delivery takes 7-8 days to most locations across India.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is your return and warranty policy?\u003c\/summary\u003e\n\u003cp\u003eWe offer a 7-day return policy on manufacturing defects only. Contact support within 7 days of receipt for free replacement or full refund. Not applicable for user damage or misuse.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eAre bulk discounts available?\u003c\/summary\u003e\n\u003cp\u003eYes, wholesale pricing for orders of 10 or more units. Contact our sales team via WhatsApp or email for a customized bulk quote.\u003c\/p\u003e\n\u003c\/details\u003e\n\n\u003ch2\u003eWhy Buy from The Tech Depot\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine Products: Sourced directly from authorized distributors with authentication\u003c\/li\u003e\n\u003cli\u003eExpert Team: Our technical team validates every product before listing\u003c\/li\u003e\n\u003cli\u003eFast Shipping: Dispatched within 1-5 days from our Bengaluru warehouse\u003c\/li\u003e\n\u003cli\u003ePan-India Delivery: 7-8 days to Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata\u003c\/li\u003e\n\u003cli\u003ePayment Options: COD, UPI, credit\/debit cards, net banking, EMI available\u003c\/li\u003e\n\u003cli\u003eTechnical Support: 24\/7 expert guidance via email and WhatsApp\u003c\/li\u003e\n\u003cli\u003eReturns: 7-day return policy on manufacturing defects only\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eBuy Kamoer KCP- C -LAB PUMP – S06 Peristaltic Pump Online in India\u003c\/h2\u003e\n\u003cp\u003ePurchase the \u003cstrong\u003eKamoer KCP- C -LAB PUMP – S06 Peristaltic Pump\u003c\/strong\u003e online at \u003ca href=\"https:\/\/thetechdepot.in\"\u003eThe Tech Depot\u003c\/a\u003e, India's trusted source for genuine electronics. We deliver across Bengaluru, Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata, Ahmedabad, Jaipur, and Surat. Get the best price on \u003cstrong\u003eKamoer KCP- C -LAB PUMP – S06 Peristaltic Pump\u003c\/strong\u003e with fast shipping and expert support.\u003c\/p\u003e\n\u003cp\u003eOur team in Bengaluru is available 24\/7 to support your journey from product selection to project completion.\u003c\/p\u003e","brand":"The Tech Depot","offers":[{"title":"Default Title","offer_id":48742496469249,"sku":"TTD-5693","price":3494.82,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/1577\/3185\/files\/5b1e62f9dddc83b373c0aa8cfa5c80f9.jpg?v=1778028727","url":"https:\/\/techdepot.in\/products\/kamoer-kcp-c-lab-pump-s06-peristaltic-pump","provider":"Tech Depot India","version":"1.0","type":"link"}