{"product_id":"flat-ribbon-cable-100ft-roll-26-pin-26-conductors-frc-computer-cable","title":"Flat Ribbon Cable 100ft Roll - 26 Pin - 26 conductors - FRC Computer Cable","description":"\u003cmeta name=\"description\" content=\"Buy Flat Ribbon Cable 100ft Roll - 26 Pin - 26 conductors - FRC Computer Cable online in India at best price from The Tech Depot, Bengaluru. Authentic product, 7-day warranty on manufacturing defects, fast delivery across India.\"\u003e\n\n\u003ch1\u003eFlat Ribbon Cable 100ft Roll - 26 Pin - 26 conductors - FRC Computer Cable\u003c\/h1\u003e\n\n\u003cp\u003eThe Flat Ribbon Cable 100ft Roll is a professional-grade FRC (Flat Ribbon Conductor) cable featuring 26 individual conductors, designed for high-density parallel data transmission in computer systems and industrial equipment. This cable is extensively used by electronics engineers, system integrators, and IT professionals who require reliable multi-conductor connectivity for legacy and modern computing applications. It solves the critical challenge of organizing multiple signal lines in compact spaces while maintaining signal integrity and reducing electromagnetic interference across parallel data buses.\u003c\/p\u003e\n\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eFlat ribbon cables operate on the principle of parallel conductor arrangement, where 26 individual copper conductors are laminated together in a flat profile with insulating material. This configuration enables simultaneous transmission of 26 independent signals, making it ideal for parallel communication protocols such as IDE\/PATA interfaces, printer connections, and industrial control systems. The flat geometry allows for easy routing through tight spaces, cable management in server racks, and simplified termination using IDC (Insulation Displacement Connector) technology without requiring individual wire stripping.\u003c\/p\u003e\n\n\u003cp\u003eThis 100-foot roll provides exceptional value for large-scale installations, system builds, and industrial projects where multiple connection points are required. The 26-conductor configuration supports legacy computer systems, vintage computing restoration, industrial automation equipment, and custom electronics projects. Superior conductor spacing maintains consistent impedance characteristics, while the durable PVC insulation resists abrasion, moisture, and moderate chemical exposure. The extended length eliminates the need for multiple shorter cables and splices, ensuring cleaner installations and superior signal fidelity across the entire run.\u003c\/p\u003e\n\n\u003ch2\u003eKey Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecification\u003c\/td\u003e\n\u003ctd\u003eDetails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFlat Ribbon Cable (FRC) - 26 Conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e100 feet per roll\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Conductors\u003c\/td\u003e\n\u003ctd\u003e26 individual copper conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Gauge\u003c\/td\u003e\n\u003ctd\u003e28 AWG (0.32mm diameter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Material\u003c\/td\u003e\n\u003ctd\u003eTinned copper for corrosion resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Material\u003c\/td\u003e\n\u003ctd\u003ePVC (Polyvinyl Chloride)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Width\u003c\/td\u003e\n\u003ctd\u003eApproximately 2.54 inches (64.5mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePitch Between Conductors\u003c\/td\u003e\n\u003ctd\u003e0.10 inches (2.54mm) standard IDC spacing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-20°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300V maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance\u003c\/td\u003e\n\u003ctd\u003e110 ohms nominal for controlled applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eOriginal\/Authentic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e7 days on manufacturing defects\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping\u003c\/td\u003e\n\u003ctd\u003e1-5 days from Bengaluru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelivery\u003c\/td\u003e\n\u003ctd\u003e7-8 days across India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport\u003c\/td\u003e\n\u003ctd\u003e24\/7 via Email and WhatsApp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e26 Individual Conductors with 0.10-inch IDC spacing for standard connector compatibility with legacy and modern termination systems\u003c\/li\u003e\n\u003cli\u003e100-foot continuous roll eliminates splice points and maintains consistent signal integrity across extended cable runs for industrial installations\u003c\/li\u003e\n\u003cli\u003eTinned copper conductors provide superior corrosion resistance and enhanced solderability for custom termination and harsh environment applications\u003c\/li\u003e\n\u003cli\u003eFlat profile design enables efficient cable routing through narrow conduits, server rack channels, and compact equipment enclosures\u003c\/li\u003e\n\u003cli\u003ePVC insulation rated for 300V operation with -20°C to +80°C temperature range suitable for both indoor and temperature-controlled industrial environments\u003c\/li\u003e\n\u003cli\u003eStandard 110-ohm impedance characteristics support reliable parallel data transmission for IDE, PATA, and custom parallel bus protocols\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications and Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLegacy Computer Systems: Connecting IDE\/PATA hard drives, optical drives, and floppy drives in vintage computers and retro computing restoration projects requiring authentic parallel interface cables\u003c\/li\u003e\n\u003cli\u003eIndustrial Automation: Multi-signal control lines in PLC systems, industrial machinery, and process control equipment where 26 parallel control signals must be transmitted reliably\u003c\/li\u003e\n\u003cli\u003ePrinter and Peripheral Connections: Parallel printer interfaces, scanner connections, and legacy peripheral devices requiring 26-conductor parallel communication protocols\u003c\/li\u003e\n\u003cli\u003eCustom Electronics Projects: Robotics systems, embedded systems, and experimental electronics requiring flexible multi-conductor parallel buses for sensor arrays and control signal distribution\u003c\/li\u003e\n\u003cli\u003eServer and Data Center Infrastructure: Internal system interconnections, backplane connections, and legacy server equipment requiring high-density parallel conductor arrangements\u003c\/li\u003e\n\u003cli\u003eEducational and Laboratory Applications: Electronics training, signal integrity testing, and experimental setups requiring configurable multi-conductor parallel transmission media\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003cp\u003eBegin by measuring the required cable length between your source and destination connectors, accounting for routing path and slack for future adjustments. Cut the ribbon cable to length using a sharp utility knife or cable cutter, ensuring a clean perpendicular cut to prevent conductor fraying. For IDC connector termination, align the cable with the connector's 0.10-inch pitch guides, position it squarely in the connector body, and apply firm downward pressure using the connector's actuator or crimping tool. The insulation displacement technology automatically pierces the PVC insulation and establishes contact with the tinned copper conductors without requiring individual wire stripping.\u003c\/p\u003e\n\n\u003cp\u003eFor soldered terminations, carefully separate individual conductors or small groups using a utility knife, strip approximately 0.25 inches of insulation from each conductor, tin the exposed copper with solder, and attach to your custom connector or PCB pads. Verify continuity using a multimeter across all 26 conductors before powering your system. Route the cable away from high-voltage power lines and sources of electromagnetic interference, securing it with cable clips or ties at regular intervals to prevent flexing stress. For applications requiring shielding, wrap the ribbon cable with conductive foil tape grounded at both ends to minimize EMI coupling into the parallel conductors.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is the difference between 26-conductor and other pin count ribbon cables?\u003c\/summary\u003e\n\u003cp\u003eThe 26-conductor configuration provides 26 simultaneous parallel signal lines, making it ideal for legacy IDE\/PATA interfaces and industrial systems requiring multiple control signals. Other common configurations include 16-conductor (parallel printers), 34-conductor (SCSI), and 40-conductor (IDE). The 26-pin variant is specifically optimized for applications requiring approximately 26 parallel data or control lines with standard 0.10-inch IDC spacing for universal connector compatibility.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I use this cable for high-speed data transmission?\u003c\/summary\u003e\n\u003cp\u003eThe 26-conductor ribbon cable is designed for parallel data transmission at moderate speeds typical of legacy computer systems and industrial applications, supporting data rates up to approximately 5-10 Mbps depending on cable length and termination quality. For modern high-speed applications requiring gigabit speeds, differential signaling, or twisted-pair configurations, specialized twisted-pair or shielded cables are recommended. The flat ribbon design prioritizes ease of routing and multi-conductor density over high-frequency performance.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow do I properly terminate the ribbon cable without damaging the conductors?\u003c\/summary\u003e\n\u003cp\u003eFor IDC connectors, position the cable squarely with the connector's pitch guides and apply firm, even pressure using the connector's actuator or a specialized crimping tool. Avoid twisting or angling the cable during insertion to prevent conductor displacement. For soldered terminations, use a 25-40 watt soldering iron with rosin-core solder, apply heat for 2-3 seconds per joint, and avoid excessive heat that could melt the PVC insulation. Always test continuity with a multimeter after termination to verify proper conductor contact and identify any shorts between adjacent conductors.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs this cable suitable for outdoor or harsh environment applications?\u003c\/summary\u003e\n\u003cp\u003eThe PVC insulation provides basic protection against moisture and moderate chemical exposure, with an operating temperature range of -20°C to +80°C suitable for temperature-controlled indoor and industrial environments. For outdoor, high-temperature, or chemically aggressive applications, consider upgrading to cables with polyimide or fluoropolymer insulation and UV-resistant jackets. For harsh environments, additional shielding, conduit protection, and strain relief are recommended to extend cable lifespan and maintain signal integrity.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhen will I receive my order?\u003c\/summary\u003e\n\u003cp\u003eOrders are dispatched within 1-5 business days from our Bengaluru warehouse. Delivery takes 7-8 days to most locations across India.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is your return and warranty policy?\u003c\/summary\u003e\n\u003cp\u003eWe offer a 7-day return policy on manufacturing defects only. Contact support within 7 days of receipt for free replacement or full refund. Not applicable for user damage or misuse.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eAre bulk discounts available?\u003c\/summary\u003e\n\u003cp\u003eYes, wholesale pricing for orders of 10 or more units. Contact our sales team via WhatsApp or email for a customized bulk quote.\u003c\/p\u003e\n\u003c\/details\u003e\n\n\u003ch2\u003eWhy Buy from The Tech Depot\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine Products: Sourced directly from authorized distributors with authentication\u003c\/li\u003e\n\u003cli\u003eExpert Team: Our technical team validates every product before listing\u003c\/li\u003e\n\u003cli\u003eFast Shipping: Dispatched within 1-5 days from our Bengaluru warehouse\u003c\/li\u003e\n\u003cli\u003ePan-India Delivery: 7-8 days to Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata\u003c\/li\u003e\n\u003cli\u003ePayment Options: COD, UPI, credit\/debit cards, net banking, EMI available\u003c\/li\u003e\n\u003cli\u003eTechnical Support: 24\/7 expert guidance via email and WhatsApp\u003c\/li\u003e\n\u003cli\u003eReturns: 7-day return policy on manufacturing defects only\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eBuy Flat Ribbon Cable 100ft Roll - 26 Pin - 26 conductors - FRC Computer Cable Online in India\u003c\/h2\u003e\n\u003cp\u003ePurchase the \u003cstrong\u003eFlat Ribbon Cable 100ft Roll - 26 Pin - 26 conductors - FRC Computer Cable\u003c\/strong\u003e online at \u003ca href=\"https:\/\/thetechdepot.in\"\u003eThe Tech Depot\u003c\/a\u003e, India's trusted source for genuine electronics. We deliver across Bengaluru, Mumbai, Delhi, Chennai, Hyderabad, Pune, Kolkata, Ahmedabad, Jaipur, and Surat. Get the best price on \u003cstrong\u003eFlat Ribbon Cable 100ft Roll - 26 Pin - 26 conductors - FRC Computer Cable\u003c\/strong\u003e with fast shipping and expert support.\u003c\/p\u003e\n\u003cp\u003eOur team in Bengaluru is available 24\/7 to support your journey from product selection to project completion.\u003c\/p\u003e","brand":"The Tech Depot","offers":[{"title":"Default Title","offer_id":48741329174785,"sku":"TTD-4108","price":1298.71,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/1577\/3185\/files\/423c3fd802cd52789277a03e0ef10881.jpg?v=1778023675","url":"https:\/\/techdepot.in\/products\/flat-ribbon-cable-100ft-roll-26-pin-26-conductors-frc-computer-cable","provider":"Tech Depot India","version":"1.0","type":"link"}